FireCell

0

EMS FireCell is EN54-35 compliant and the next generation of wireless fire alarm detection utilizing leading edge ‘Smart Cluster Technology. It ensures ease-of-use for the installation and extensive wireless coverage. This is simply not merely a new system, but a huge advancement for the automatic wireless fire detection industry.

New Era
EMS is at the cutting edge of wireless radio fire systems development ever since the introduction of radio communication within the field of fire safety. At this time, EMS is recognized as one of the leading high-tech specialist, developer and producer of wireless fire alarm systems in the UK. FireCell signifies a wireless revolution and the beginning of a new era!

EMS was directly associated with formulating the latest standard by supplying technical expertise towards the working team whose job was to bring together the UK and European wireless industries.

Installer liability.
The demands of EN54-25 exceed equipment compliance. The installer / maintainer obligation is to make sure that the wireless communication system satisfies the signal loss immunity specifications recommended by EN54-25.

What is FireCell?
Developed upon the achievements the 5000 FirePoint wireless fire alarm system, the creation of FireCell is a different technology developed as a short-range, Mulit-directional communication link in between fire devices.

Smart Cluster Technology:
In order to meet the demands of the EN54-25 accreditation, the FireCell system contains a new communication device: EMS’s exclusive ‘Smart Cluster Technology’. This technology, created by EMS at our factory in the UK, allows FireCell to satisfy EN54-25 without having interconnecting cables.

Smart Cluster Technology (SCT) utilizes a multi-frequency link, created to eradicate signal obstruction and signal impact, permitting carefully synchronised transmissions, with multi route availability. This enables an increased margin of signal power to be preserved through the entire system.

Communication management:
The European Standard recommends a significant signal above what is needed at survey and installation. EN54-25 demands a signal above 20-30db. This is in between 100-1,000 times the tolerance fault tolerance of ordinary communication!

FireCell features a complex new element, allowing the signal overhead to be inspected at any moment. If the communication signal from a sensor is discovered to be below normal, the Smart Cluster Technology automatically increases the transmission power, therefore restoring the communication route.

Firecell is manufactured in the UK
EMS is very proud of its ‘made in Britain’ reputation; FireCell is produced and constructed in its manufacturing area in Herne Bay, Kent. The highest quality and credibility of EMS products is widely known.